BONA-GM-T01-Lab-Scale TFF Ultrafiltration System

BONA-GM-T01 Lab-Scale TFF Ultrafiltration System - TFF Systems - BonaTech Description:BONA-GM-T01 lab-scale tangential flow ultrafiltration system handles 50 mL minimum working volume with 0.1 m² membrane area. Manual, cost-effective crossflow UF for early R&D, sample concentration and clarification. BonaTech.

  • Minimum Operating Volume50 mL
  • Effective Filtration Area0.1 m²
  • Operating Temperature5-55 °C
  • pH Range2-12
  • Material Tank1.1 L (sealed)
  • Flow Rate0.1-10 L/h

Product Overview

Crossflow Filtration Mode Enables Ultra-Long-Duration Filtration

Membrane separation experiments adopt crossflow filtration, where the feed flows at high velocity along the membrane surface, effectively overcoming concentration polarization and fouling accumulation, mitigating membrane surface fouling, maintaining high-flux filtration, and enabling ultra-long-duration filtration.

Operates at Room Temperature, Ideal for Heat-Sensitive Substances

The membrane separation process is carried out at room temperature, with no phase change and no heating, making it particularly suitable for the separation and concentration of heat-sensitive substances, and preserving the activity and stability of the target product to the greatest extent.

Pressure-Driven, Easy to Operate and Maintain

Driven by pressure as the motive force for membrane separation, the unit features a simple structure and easy operation; all parameters can be automatically adjusted, making it easy to control and maintain, and suitable for high-frequency daily use in the laboratory.

Phase-Change-Free Separation, One Unit for Multiple Experimental Goals

The separation process involves no phase change and can achieve various experimental goals such as separation and purification, desalination, decolorization, dealcoholization, and concentration of aqueous feed streams. This unit can also be retrofitted with microfiltration, ultrafiltration, and nanofiltration membrane cassettes, covering multiple separation-precision requirements with a single device.

Wide Range of Applications

Widely used in pharmaceuticals, food, health products, biologics, blood products, enzyme preparations, cosmetics, synthetic biology, nanomaterials, new energy, new materials, and other fields, meeting the membrane separation experimental needs of different industries.

Minimal Recirculation Volume—Experiments Completed with Just a Few Hundred Milliliters

With a minimal recirculation volume, only a few hundred milliliters of feed are required to complete a membrane separation experiment, significantly reducing sample consumption and experimental cost, making it the optimal choice for laboratory membrane separation experiments.

Standard Configuration

One peristaltic pump (1 unit)
one SUS316L stainless steel membrane holder (1 unit)
one membrane cassette (1 unit)
two pressure gauges (2 sets)
one material tank (1 unit)
one pressure regulating valve (1 unit)
equipment support frame
connecting clamps
piping and fittings (several)

Technical Specifications

Recommended Models

Typical Applications

Tangential Flow Filtration (TFF) achieves separation by flowing the feed tangentially across the membrane surface. Compared with dead-end filtration, it better suppresses membrane fouling and maintains stable flux, and is widely used for clarification, concentration, purification, desalting, and buffer exchange of biomacromolecules. Typical application directions are listed below:

01

Clarification Filtration of Biological Samples

Used for clarifying cells, cell debris, microbial lysates, and TCM aqueous extracts, effectively removing impurities to ensure the smooth progress of downstream biological processes such as protein salting-out.

02

Protein and Antibody Concentration and Purification

For biomacromolecules such as albumin, recombinant proteins, antibodies, ADC drugs, and coagulation factors, the tangential-flow ultrafiltration system provides efficient concentration solutions, while also suitable for the separation and enrichment of viruses, microspheres, cell supernatants, and nanoparticles.

03

Desalting and Buffer Exchange for Macromolecule Drugs

In the preparation of biological products such as nucleic acids, peptides, insulin, interferon, and growth hormone, Tangential Flow Filtration enables rapid desalting and impurity removal, meeting the high-purity requirements of materials such as chondroitin sulfate.

04

Buffer Exchange and Exosome Processing

The tangential flow system efficiently performs buffer exchange for viruses, plasmids, oligonucleotides, and lipid nanoparticles; it is especially suitable for the gentle separation and system conversion of sensitive materials such as exosomes, hyaluronic acid, and sodium heparin.

05

Pyrogen Removal for Injection-Grade Drugs

For injectable APIs, biomacromolecule drugs, TCM injections, and pharmaceutical excipients, the tangential flow system provides professional pyrogen removal, ensuring process water and buffers meet stringent pharmacopeia standards.

06

Separation and Purification for Vaccines and Gene Therapy

In vaccine R&D and genetic engineering, the Tangential Flow Filtration system provides one-stop tangential-flow process support — from cell harvest to concentration and purification — for viral vectors, nucleic acid drugs, and recombinant proteins.

Get a Custom Solution & Quote for BONA-GM-T01

Tell our engineers about your requirements — we'll get back to you with a custom solution and model recommendation within 1 business day.

400-680-4339